■Handles wide range of samples,cell culture, plants, fish etc.
Features ・For use with inverted microscopes
・Preset specimen temperature range 20℃-40℃
Long Working Distance / Dry lens: 15℃-40℃
Short Working Distance, oil/water immersion lens: 20℃-40℃
・Sample Temperature Feedback Control(Pat.P)
Allows precise specimen temperature adjustment. Possible to
adjust sample temperature close to ambient. This system
has both cooling and heating function and by automatically shifting
the function, it allows stable and smooth ambient temperature control.
NOTE: Under room temperature of 25.0 degree C ±2.0 degree C.
Determines optimal Stage Heater temperature Setting Value for room
temperature during preliminary operation and incubates sample without
inserting Sensor into a dish during operation.
Neco's exclusive software outputs sample temperature to PC.
・Wide range of applicable dishes
Model
INUCP-KRi-F1
With a gas flowmeter
for premixed gas.
INUCP-KRi
Temperature regulation only
(no gas function)
NOTE:Select optional Digital Gas Mixing System
if application requries.
Optimal for time-lapse fluorescence observation on the level of 1 molecule.
System keeps focus drift to a minimum from TIRF time-lapse imaging.
Corresponds to TIRF objective 60x -100x.
Provides uniform temperature distribution during Heating & Cooling
NOTE: 35mm dish with 2ml water
Heating: 37℃
Cooling: 20℃
With Sample Feedback Control, it is stable against with temperature changes and keeps
optimal temperature at all times
NOTE: 35mm dish with 3ml water
Dish Attachment
Heating only
Cooling/Heating
For 35mm dish
: KRiH-D35
KRi-D35
For 35mm dish x 2pc
: KRiH-D35-2
KRi-D35-2
For 50/60mm dish
: KRiH-D56
KRi-D56
For chamber slide and slide glass
: KRiH-SC
KRi-SC
For chambered coverglass
: KRiH-CGC
KRi-CGC
NOTE:
1.One of Dish Attachment is included as standard feature.
Select one from Cooling/Heating Dish Attachment line.
2.Cooling/Heating Dish Attachment has 22mm diameter opening
for cooling effect and it has a heat insulating material at bottom.
3.Heating only Dish Attachment has 28mm diameter opening.
Stage Adapter for manual stage with round opening
For cross stage, rectangulal stage
: MK-RA
Exclusive Sensor Lid (with a sterilizable Feedback Sensor)
Sensor Lid for 35mm dish
: D35-200F
Sensor Lid for 50/60mm dish
: D56-200F
Sensor Lid for chamber slide
: CS-200F
Sensor Lid for chambered coverglass
: CGC-200F
Temperature Feedback Sensor (300mm)
: TSU-200F
Lead line(1500mm)
: HD1500
PC operating system requirement :Windows 7 / Vista (32/64bit) Windows XP SP2 / SP3
Interface:RS-232C
Enables to output and log the sample & Chamber Unit environmental temperature during time-lapse.
Temperature & Gas management
Neco allows to adjust temperature and gas concentration by PC.
Real time monitoring and logging
Display and record real time
temperature and CO2.
Sampling data is saved in CSV file
Display channels
6 channels for temperature 2 channels for gas (CO2 & O2).
NOTE: To change, monitor and log gas concentration rate via PC,
GM-4000A/E or GM-8000 are required with Neco System.